Page tree
Skip to end of metadata
Go to start of metadata

Use the options in this dialog box to define if and how neoMatch may manage measurements done with spectrophotometer. 


Preferences

From menu neoMatch | Preferences… you can open the preferences box. 


  • You can find settings for the minimum and maximum dE value in the color matching process. We recommend maximum of dE 3.
  • DeltaE Type provides the CIE types: dE76, dE94 (Graphic Arts), dE94 (Textiles), dE2000, CMC (1:1) and CMC (2:1). By default is dE94 (Textiles).
  • The Render Method is using the default rendering intent method Perceptual. Other available methods: Absolute Colorimetric, Saturation, Relative Colorimetric.
  • Bits Per Component gives you option to export in LAB 8bits or LAB 16bits.
  • Option to generate and export all image files using neoRipEngine.
  • Font type and size selection which is used in export image file. By default is 'Dejavu Sans Condensed' and size 8.


Name formatter

From menu Measure | Show Name Formatter… you will reach a dialog to set up the formatter, with help of the formatter text below. 



Chromatic Adaption of White

From menu Utilities | Chromatic Adaption… you will reach the dialog to set up the white reference to the ICC profile white.